1. Make sure scale is OFF. Remove the platter assembly (metal and plastic platform.)
2. On the right hand side you will find a hole and a screw at the bottom. This is the SEALING BOLT. Please remove the SEALING BOLT and then turn the scale upside-down to find the CALIBRATION BOLT and PLATE located on the right side of the bottom of the scale (if keyboard is facing you and you tilt the scale upwards by the front.)
3. Remove the CALIBRATION BOLT and the silver PLATE. Under the PLATE you will see the calibration button: SW#1.
4. Press and hold down SW#1 then press the ON/OFF key.
5. The display will show . Release SW#1 and place the platter assembly (metal and plastic platform) back onto the scale.
6. Press the ON/OFF key. The display will show , and then show . The scale may show a different value (1-21, 1-22, 1-23, 1-24.)
7. There are 3 program entries 1, 2, and 3. These are indicated by the digit to the left of the dash. Each of these entries takes a 2-digit value that determines the options for the scale. This documents lists ONLY the default or standard USA model settings. To change options use the following keys:
UNIT This key changes the value of the right-most digit. It ranges from 0 to F (hexadecimal.) TARE This key multiplies the value to the right of the dash by 10. ZERO This key stores the current settings value and moves on to the next setting.
8. Make sure that you select the correct settings for your scale. DO NOT set the scale to a different capacity than the scale is rated for as this will cause irreversible damage to the load cell. (See chart.)
5 lb or 2 kg 10 lb / 5 kg 20 lb / 10 kg 50 lb / 25 kg 1-21 1-22 1-23 1-24 2-12 2-12 2-12 2-12 3-42 3-42 3-42 3-42
9. Once you are at program 3 , press the ZERO key and the display will read and then go blank.
10. Press the ON/OFF key until the display reads , and then follow the instructions for SPAN CALIBRATION FOR SW-Series starting from step 8.
Смотри не смотри но вот это точно что есть только 20 кг а 25 нет. Это сто процентов. Сам видел и работал с ними. Выслал тебе сервисную самому смотреть некогда. Но scalemaster прав, запиши старые сеты и меняй другими так и выйдешь на нужный результат.
Здравствуйте! Помогите пожалуйста, нужна схема на SW-1(10кг) и по возможности сервисную инструкцию.....проблема заключаеться в зависании....на индикаторе отображаються все элементы....питание в норме....кварцевый генератор работает...
Все даты в формате GMT
3 час. Хитов сегодня: 27
Права: смайлы да, картинки да, шрифты нет, голосования нет
аватары да, автозамена ссылок вкл, премодерация откл, правка нет